ZR-3330 Ambient air CO Analyzer

ZR-3330 ambient air carbon monoxide (CO) analyzer is a portable device to monitor CO in the atmospheric by Non dispersive infrared (NDIR) method.

Request a Quote

PRODUCTS DETAILS

product detail

This analyzer is widely used for outdoor long-term continuous automatic sampling analysis. It is used in routine ambient air quality monitoring, environmental assessment, scientific research, emergency monitoring, and air quality monitoring station data comparison.

Application>>

Application.jpg

Principle

Non dispersive infrared spectroscopy (ND-IR) is often used to detect gas & measure the concentration of carbon oxides (e.g. carbon monoxide, carbon dioxide). An infra-red beam passes through the sampling chamber and each gas component in the sample absorbs some particular frequency infra red.

yuanli.jpg

Features

Powerful function and ensure data stable

> Equipped with precision infrared light sources and optical sensors, ensure long service life and effective anti-interference.

> Uses a built-in inert PTFE sample inlet filter, which do not adsorb or react with the measured gas components.

> Adaptive filtering algorithm, fast response, low detection limit, high sensitivity.

> Measure environmental temperature, humidity, pressure, and provide real-time compensation for temperature and pressure, suitable for stable and accurate monitoring in different conditions.

xiangqing.jpg

Users friendly

> Datas can be switched to ppb, ppm, ppb, μmol/mol, μg/m3, mg/m3

> 7-inch touch screen, easy to operation.

> Zero point and span calibration can be performed manually.

> Store over 250000 data, check and print the data in real time by Bluetooth printer and exported by USB.

> Support GPS and 4G remote data upload.


Excellent protective performance

> Lightweight, easy to carry and install, rainproof and dustproof.

> A rugged IP65 weatherproof enclosure provides optimal performance, even in extreme conditions, purpose-built for the outdoors, unmanned monitoring.

Technical Parameter

Parameter

Range

Resolution

CO concentration

(0~50)ppm

0.01ppm

Sampling flowrate

800 mL/min

1mL/min

Zero point noise

≤0.05ppm

Minimum detection limit

0.1ppm

Linearity

±1 % F.S.

Zero drift

±1 ppb

Span drift

±1% F.S.

Span noise

≤0.1ppm

Indication error

±2%FS

Flow stability

≤90s

Voltage stability

±1%FS

Effect of ambient temperature changes

≤0.1 ppm /℃

Data storage

250000组

Battery working time

>4h

Dimensions

(L390×W278×H555)

Host weight

About 18.5kg

Power supply

≤200W

Consumption

AC(220±22)V,(50±1)Hz

Working condition

(-20~50)℃

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours